Temperature & Humidity

Wall Mount
Cost Efficient HMW80 / TMW80 series
  • Accuracy: ±3% rH, ±0.5 C

  • Optional display

  • Vaisala INTERCAP® Humidity Sensor

  • Temperature only model:

    • TMW82, TMW88

  • Humidity and Temperature model:

    • HMW82P100,

    • HMW82, HMW83,

    • HMW88, HMW88D,

    • HMW89, HMW89D

Wall Mount
HMW110 series
  • Accuracy: ±2% rH, ±0.2 C

  • Optional display

  • Vaisala HUMICAP® Humidity Sensor

  • Temperature only model:

    • TMW110

  • Humidity and Temperature model:

    • HMW110

    • HMW112

Wall Mount
High Performance HMW90 series
  • Accuracy: ±1.7% rH, ±0.2 C

  • Display with or without sliding cover

  • Vaisala HUMICAP® Humidity Sensor

  • Temperature only model:

    • TMW90, TMW92, TMW93

  • Humidity and Temperature model:

    • HMW92, HMW92D

    • HMW93, HMW93D

    • HMW90

    • HMW95, HMW95D

Wall Mount
Clean Room HMT120 / HMT130 series
  • Accuracy: ±1.5% rH, ±0.1 C

  • Optional Display

  • Remote Probe options

  • Vaisala HUMICAP® Humidity Sensor

  • Temperature only Current output model:

    • TMT120

  • Temperature only Voltage output model

    • TMT130

  • Humidity and Temperature Current output model:

    • HMT120

  • Humidity and Temprature Voltage output model:

    • HMT130

Duct Mount
Cost Efficient HMD80 series
  • Accuracy: ±3% rH, ±0.5 C

  • Optional display

  • Vaisala INTERCAP® Humidity Sensor

  • Temperature only model:

    • TMD82

  • Humidity and Temperature model:

    • HMD82

    • HMD83, HMD83D

Duct Mount
HMD110 series
  • Accuracy: ±2% rH, ±0.2 C

  • Optional display

  • Vaisala HUMICAP® Humidity Sensor

  • Temperature only model:

    • TMD110

  • Humidity and Temperature model:

    • HMD110

    • HMD112

Duct Mount
High Performance HMD60 series
  • Accuracy: ±1.5% rH, ±0.1 C

  • IP66 Metal casing

  • Vaisala HUMICAP® Humidity Sensor

  • Temperature only model:

    • TMD60,

    • TMD62

  • Humidity and Temperature model:

    • HMD60

    • HMD62

    • HMD65

HVAC Transmitter

Outdoor Mount
Cost Efficient HMS80 series
  • Accuracy: ±3% rH, ±0.5 C

  • with Radiation Shield

  • Vaisala INTERCAP® Humidity Sensor

  • Temperature only model:

    • TMS82

  • Humidity and Temperature model:

    • HMS82, HMS82C

    • HMS83, HMS83C

Outdoor Mount
HMS110 series
  • Accuracy: ±2% rH, ±0.2 C

  • with Radiation Shield

  • Vaisala HUMICAP® Humidity Sensor

  • Humidity and Temperature model:

    • HMS110

    • HMS112

Duct Mount
TMI110
  • Measurement range: -40 to 120 C

  • Accuracy: ±0.1 C (20 C)

  • Immersion

Wall Mount
Cost Efficient XMW85 series
  • Accuracy: ±3% rH, ±0.5 C

  • Optional display

  • Vaisala INTERCAP® Humidity Sensor

  • Humidity, CO2 and Temperature 3-in-1 model:

    • HMW85GD (with metric dipplay)

    • HMW85GE (with non-metric display)

    • HMW85G (No display)

  • Humidity and Temperature model:

    • HMW85HD (with metric dipplay)

    • HMW85HE (with non-metric display)

    • HMW85H (No display)

General

HVAC

Temperature & Humidity

Display and Transmitter
Indigo200 series
  • For Indoor

  • Plastic housing

  • Optional display

  • Indigo201: Three analog outputs

  • Indigo202: RS-485, Modbus RTU outputs

Display and Transmitter
Indigo300 series
  • IP66, corrosion-resistant metal housing

  • Optional Display

  • Three analog outputs

Display and Transmitter
Origo10 series
  • IP65 rated enclosure

  • Optional Display with up to four parameters

  • Cleanroom compatible

  • Analog, Modbus RTU, BACnet MS/TP output options

  • Wall and Duct Mounting Options

  • Humidity, Temperature, Carbon Dioxide and Dewpoint Measurements

Display and Transmitter
Indigo520 series
  • IP66, corrosion-resistant metal housing

  • Optional Touchscreen Display

  • Dual Probe option

  • Web Interface

  • Vaisala cloud connectivity

  • Four analog outputs

  • Two SPDT relay outputs

  • Modbus TCP/IP output

  • Humidity, Temperature, Carbon Dioxide and Dewpoint Measurements

Industrial Transmitter

Display and Transmitter
Indigo510 series
  • IP66, corrosion-resistant metal housing

  • Optional Touchscreen Display

  • Web Interface

  • Vaisala cloud connectivity

  • Two analog outputs

  • Modbus TCP/IP output
    Humidity, Temperature, Carbon Dioxide and Dewpoint Measurements

Humidity and Temperature Probe
HMP1
  • Accuracy: ±1% rH, ±0.2 C

  • Vaisala HUMICAPR2® Humidity Sensor

  • Attached Probe

  • Able to operate independently with Modbus RTU over RS-485 output

  • Vaisala Indigo Family probe

Humidity and Temperature Probe
HMP3
  • Accuracy: ±0.8% rH, ±0.1 C

  • Vaisala HUMICAPR2® Humidity Sensor

  • General purpose probe with optional duct mounting kit

  • Able to operate independently with Modbus RTU over RS-485 output

  • Vaisala Indigo Family probe

Humidity and Temperature Probe
HMP4
  • Accuracy: ±0.8% rH, ±0.1 C

  • Vaisala HUMICAPR2® Humidity Sensor

  • High pressure model up to 100 bar with mounting screw

  • Maximum operating temperature of probe head: -70 to 180C

  • Able to operate independently with Modbus RTU over RS-485 output

  • Vaisala Indigo Family probe

Humidity and Temperature Probe
HMP5
  • Accuracy: ±0.8% rH, ±0.1 C

  • Vaisala HUMICAPR2® Humidity Sensor

  • Maximum operating temperature of probe head: -70 to 180C

  • Able to operate independently with Modbus RTU over RS-485 output

  • Vaisala Indigo Family probe

Humidity and Temperature Probe
HMP7
  • Accuracy: ±0.8% rH, ±0.1 C

  • Vaisala HUMICAPR2® Humidity Sensor

  • with heating function for wet environment

  • Pair with TMP1 for measurement of extreme wet environment

  • Able to operate independently with Modbus RTU over RS-485 output

  • Vaisala Indigo Family probe

Humidity and Temperature Probe
HMP8
  • Accuracy: ±0.8% rH, ±0.1 C

  • Vaisala HUMICAPR2® Humidity Sensor

  • Pipe Mount with screw and optional hot tap ball valve

  • Able to operate independently with Modbus RTU over RS-485 output

  • Vaisala Indigo Family probe

Humidity and Temperature Probe
HMP9
  • Accuracy: ±0.8% rH, ±0.1 C

  • Vaisala HUMICAPR2® Humidity Sensor

  • Miniature with rapid response time

  • Able to operate independently with Modbus RTU over RS-485 output

  • Vaisala Indigo Family probe

Temperature Probe
TMP1
  • Accuracy: ±0.06C

  • Pair with HMP7 for measurement of extreme wet environment

  • Able to operate independently with Modbus RTU over RS-485 output

  • Vaisala Indigo Family probe

Humidity and Temperature Probe
HMP155
  • Accuracy: ±0.1% rH ±0.1 C (0-90 % rH, 15 to 25 C),

  • Vaisala HUMICAPR2® Humidity Sensor

  • Optional warmed humidity probe and chemical purge

  • Meteorology grade

General

Temperature & Humidity

for quick inspections and spot-cheking
HM40 series
  • Accuracy: ±1.5% rH, ±0.2C

  • Models:

    • HM41 attached probe

    • HM42 remote 230mm long probe with spiral cord

    • HM45 remote short probe with spiral cord

    • HM46 remote 320mm long probe with spiral cord

for field sampling and calibration,
data analysis and diagnoctics
Indigo80 series
  • Colour screen

  • Calibrator for Indigo300, Indigo510 and Indigo520

  • Models:

    • HMP80 with humidity and temperature probe

    • DMP80 with dewpoint probe

    • GMP80 with Carbon Dioxide CO2 probe

  • Compatible with other Indigo family probe

Portables

Temperature & Humidity

Intrinsically Safe for use up to zone 0 and 20
HMT370EX series
  • Accuracy: ±0.8% rH, ±0.1C

  • Probes:

    • HMP371 for wall mounting

    • HMP373 for confined space

    • HMP374 for high pressure

    • HMP375 for high temperature

    • HMP377 for high humidity

    • HMP378 for pressurized pipelines

  • Ex classifications by region

    • Europe: ATEX

    • International: IECEx

    • Japan: CML

    • China: NEPSI

    • Korea: KCs

    • US: FM

    • Canada: FM

    • UK: UKEX

Explosion Proof Transmitter

Temperature & Humidity

Cost Efficient HMP63
  • Accuracy: ±3% rH, ±0.5 C

  • Vaisala INTERCAP® Humidity Sensor

  • Plastic housing

  • Optional RS-485 digital output supports Modbus RTU

  • Temperature only HMP63T for use with CWL100 data logger

HMP60 for volume applications
  • Accuracy: ±3% rH, ±0.5 C

  • Vaisala INTERCAP® Humidity Sensor

  • Metal housing

  • Optional RS-485 digital output supports Modbus RTU

  • Optional dewpoint output

OEM Modules & OEM Probes

High Accuracy HMP110
  • Accuracy: ±1.5% rH, ±0.1 C

  • Vaisala HUMICAP® Humidity Sensor

  • Optional RS-485 digital output supports Modbus RTU

Cost Efficient HMP113
  • Accuracy: ±1.5% rH, ±0.2 C

  • Vaisala HUMICAP® Humidity Sensor

  • Plastic housing

  • Optional RS-485 digital output supports Modbus RTU

  • Temperature only HMP63T for use with CWL100 data logger

Robust Module HMM170
  • Accuracy: ±1.5% rH, ±0.1 C

  • Vaisala HUMICAP® Humidity Sensor

  • for environment chambers and demanding conditions including vacuum or high pressure

  • with heating function

Humidity Module HMM100
  • Accuracy: ±1.5% rH, ±0.2 C

  • Vaisala HUMICAP® Humidity Sensor

  • for environment chambers

  • Outputs Dewpoint

Humidity and Temperature XMP10
  • Accuracy: ±1.0% rH, ±0.1 C

  • Vaisala HUMICAP® Humidity Sensor

  • Modbus RTU / analog (voltage) outputs

  • IP65 rated probe body

  • Metal and plastic options

  • Compatible with Origo10 transmitters

Digital Open Frame HMM105
  • Accuracy: ±1.5% rH, ±0.2 C

  • Vaisala HUMICAP® Humidity Sensor

  • I2C interface

  • Optional dewpoint output

Temperature & Humidity

Salt based calibrator
HMK15
  • Certified and ready-dosed salts

    • 11% rH : LiCl salt

    • 33% rH: MgCl2 salt

    • 75% rH: NaCl salt

    • 85% rH: KCl salt

    • 97% rH: K2SO4 salt

Calibrator

The Vaisala monitoring systems have transformed our operations. Their accuracy in temperature and humidity measurement is unmatched, ensuring compliance in our pharmaceutical processes.

John Doe

A pair of vintage-style gauges attached to a metal pipe system against a pale green background. The left gauge appears to be a pressure meter, while the right one displays increments and some text, likely indicating measurements.
A pair of vintage-style gauges attached to a metal pipe system against a pale green background. The left gauge appears to be a pressure meter, while the right one displays increments and some text, likely indicating measurements.

★★★★★

Contact Us

Headquarter (Kuala Lumpur)
Tel: +60 3 56331204 Fax: +60 3 56339033
Whatsapp: +60 16 2080697
Email: seacom@seacom.com.my

Address:
10-1, Jalan SS19/1G, 47500 Subang, Selangor, Malaysia

© 2025. All rights reserved.

Penang Office
Tel: +60 4 6424145 Fax: +60 4 6424144
Whatsapp: +60 4 6424145
Email: seacompg@seacom.com.my

Address:
A28, Persiaran Mahsuri 2, Sunway Tunas, 11900 Penang, Malaysia.

Melaka & Johor representative:
Tel / Whatsapp: +60 12 2932483
Email: seacomjb@seacom.com.my